Update Announcement
This proposal notice was updated on September 5, 2024 to advise the public that this file is still under active review. The original proposal date and comment period have not been altered.
Cette consultation a eu lieu :
du 11 février 2022
au 28 mars 2022
Résumé de la proposition
This proposal is for an amendment to Environmental Compliance Approval (sewage) No. 0522-98MLKK for Calabogie Peaks Inc. for sewage works to service the existing and proposed developments at Calabogie Peaks Resort, located at 30 Barrett Chute Road in Calabogie, Ontario.
Détails de l'emplacement
Adresse du site
30 Barrett Chute Road
Calabogie,
ON
Canada
Carte de l'emplacement du site
L'épingle de localisation correspond à la zone approximative où a lieu l’activité environnementale.
Afficher cet emplacement sur une carte opens link in a new windowPromoteur(s)
Calabogie Peaks Inc.
30 Barrett Chute Road
Calabogie,
ON
K0J 1H0
Canada
Détails de la proposition
This proposal is for an amendment to Environmental Compliance Approval (sewage) No. 0522-98MLKK for Calabogie Peaks Inc. for sewage works to service the existing and proposed developments at Calabogie Peaks Resort, located at 30 Barrett Chute Road in Calabogie, Ontario.
The proposal is to upgrade and re-rate the existing hotel subsurface sewage disposal system from a design capacity of 131,760 litres per day (43,920 litres per day per module) to 225,000 litres per day (75,000 litres per day per module) by adding new components with additional sewage connections from the existing and proposed accommodation units, as well as to upgrade the maintenance building Class 4 sewage system, with a daily design sanitary sewage flow of 4,600 litres per day.
The proposed sewage works include:
- one proposed 40,000 litre balancing tank, two proposed 60,000 litre septic tanks and new forcemains for the hotel subsurface sewage disposal system
- one 13,800 litre septic tank and nine (9) additional 6.1 metre long pipes for the maintenance building Class 4 sewage system
The proposal also includes modifications of the effluent objectives and the associated monitoring program for the hotel subsurface sewage disposal system.
Documents justificatifs
Consulter les documents en personne
Certains documents justificatifs peuvent ne pas être accessibles en ligne. Si tel est le cas, vous pouvez demander à consulter les documents en personne.
Veuillez communiquer avec le bureau mentionné ci-dessous pour savoir si les documents sont accessibles.
Communiquer avec nous
Contact
Client Services and Permissions Branch
135 St Clair Ave West
1st Floor
Toronto,
ON
M4V 1P5
Canada
Commentaire
La consultation est maintenant terminée.
La période de consultation a eu lieu du 11 février 2022
au 28 mars 2022