Greencity Limited - Environmental Compliance Approval (sewage)

Instrument type: Environmental Compliance Approval (sewage)

ERO number
019-8173
Ministry reference number
6126-CYGH8V
Notice type
Instrument
Act
Environmental Protection Act, R.S.O. 1990
Posted by
Ministry of the Environment, Conservation and Parks
Notice stage
Proposal
Proposal posted
Comment period
January 24, 2024 - March 9, 2024 (45 days) Closed
Last updated

This consultation was open from:

January 24, 2024
to March 9, 2024

Proposal summary

This proposal is for a new Environmental Compliance Approval for Greencity Limited for the establishment of subsurface disposal works, rated at 12,100 litres per day serving the Upper Rideau Resorts, located at 9748 County Road 42, in the Township of Rideau Lakes, Ontario.

Location details

Site address

9748 County Road 42
Rideau Lakes, ON
Canada

Site location map

The location pin reflects the approximate area where environmental activity is taking place.

View this location on a map opens link in a new window

Proponent(s)

Greencity Limited
9748 County Road 42
Rideau Lakes, ON
K0G 1X0
Canada

Proposal details

This proposal is for a new Environmental Compliance Approval for Greencity Limited for the establishment of subsurface disposal works, rated at 12,100 litres per day serving the Upper Rideau Resorts, located at 9748 County Road 42, in the Township of Rideau Lakes, Ontario.

The Upper Rideau Resorts consists of six seasonal small 3-bedroom waterfront cabins and one 5-bedroom multi-family dwelling which remains partially occupied throughout the year.

There are currently three class 4 wastewater treatment systems (WWTS) located on the site:

  • System 1 services two cabins utilizing two traditional septic tanks, a pump chamber, and a dosed in-ground filter bed.
  • System 2 services four cabins utilizing one traditional septic tank and a gravity fed in-ground conventional leaching bed.
  • System 3 services one 5-bedroom multi-family dwelling utilizing a traditional septic tank and a gravity fed in-ground conventional leaching bed.

The following modifications are proposed to the existing WWTS systems:

  • Upgrades to System 2, including the decommissioning of the existing in-ground conventional leaching bed, adding a new pump chamber and rerouting the effluent from four cabins to a new partially raised leaching bed comprised of type II leaching chambers.
  • Upgrades to System 3, including the decommissioning of the existing in-ground conventional leaching bed, adding a new pump chamber, and rerouting the effluent from the 5-bedroom multi-family dwelling to a new partially raised leaching bed comprised of type II leaching chambers. The new partially raised leaching bed has been designed to have the capacity to treat four 3-bedroom cabins and one 5-bedroom multi-family dwelling with a combined theoretical daily design sewage flow of 8,900 litres per day.

Supporting materials

View materials in person

Some supporting materials may not be available online. If this is the case, you can request to view the materials in person.

Get in touch with the office listed below to find out if materials are available.

Client Services and Permissions Branch
Address

135 St Clair Ave West
1st Floor
Toronto, ON
M4V 1P5
Canada

Office phone number

Comment

Commenting is now closed.

The comment period was from January 24, 2024
to March 9, 2024